About General Purpose Centrifuge
Technical Specification :
- General Purpose Bench Top Laboratory Centrifuge Machine.
- Heavy duty C.R.C. construction finished with powder coating.
- Double walled ABS injection moulded lid which is light weight to avoid accident.
- Inter lid lock and metallic centrifuge bowl for safety.
- Microprocessor based programmable speed control from 500 to 5200 r.p.m depending upon the type of rotor and Digital timer (0-59 minutes)
- 4 lines, 20 characters. LCD Display for set time, run time, set and run rpm, rcf.
- Last test parameter recall and display automatically on LCD.
- 50 programmes can be stored in memory and automatic rotor identification on display.
- Additional electronic lid lock which does not allow to open lid when machine is running and opens automatically after centrifuge time is over. Calibration window on lid.
- Dynamic brake (automatic) and imbalance detector are provided.
- election of 3 acceleration + 4 deceleration profile with fast spin option.
Efficient Sample SeparationThe General Purpose Centrifuge streamlines medical and laboratory workflows by swiftly separating blood, serum, and other biological samples. Its digital display ensures accuracy, making it a vital tool for hospitals and laboratories aiming for reliable results in diagnostics and research.
Built for Versatile Laboratory UseConstructed to meet standard laboratory requirements, this centrifuge is ideal for a range of clinical diagnostics. Its manageable size and robust construction make it easy to integrate into existing laboratory setups, ensuring consistent and long-term performance.
FAQ's of General Purpose Centrifuge:
Q: How does the digital display enhance the operation of the General Purpose Centrifuge?
A: The digital display provides precise control over speed and time settings, allowing users to monitor the process in real time. This ensures accurate and repeatable sample separation for laboratory and hospital needs.
Q: What are the primary applications of this centrifuge in hospital and clinical laboratory settings?
A: The centrifuge is primarily used for separating blood components, preparing samples for clinical analysis, and conducting research that requires separation of fluids and particles.
Q: When should routine maintenance be performed on the General Purpose Centrifuge?
A: Routine maintenance is recommended every six months or as specified in the user manual to ensure optimal performance and extend the lifespan of the equipment.
Q: Where can I purchase the General Purpose Centrifuge in India?
A: This centrifuge is available through a comprehensive network of dealers, distributors, manufacturers, and suppliers across India. You can also contact authorized exporters, fabricators, traders, and wholesalers for purchasing options.
Q: What is the process for using the centrifuge in a laboratory?
A: Place the prepared sample tubes into the rotor, select the desired speed and time using the digital display, secure the lid, and start the centrifugation. After completion, safely remove the samples for further analysis.
Q: How does the 1-year warranty benefit purchasers of the centrifuge?
A: The 1-year warranty provides assurance of product quality and covers potential manufacturing defects. During this period, users can seek repairs or replacement as per warranty terms, ensuring uninterrupted laboratory operations.
Q: What advantages does using a standard-sized and white-colored centrifuge provide in the lab environment?
A: The standard size allows easy integration into laboratory benches and workflows, while the white color promotes a clean, professional appearance that aligns with hospital and laboratory aesthetics.